Entry declarations below are shown as written, before macro expansion. Conditional entries require the corresponding options. See the reference guide for naming, direction and inclusion rules.
Source: hardware/Baumer/ecmcEAx580.cmd
| Entry identifier | Type | Direction | Object / data source | Condition prefix | Source |
|---|---|---|---|---|---|
positionActual01 | U32 | Input (slave → master) | 0x6004:0x00 (PDO 0x1a04, SM 3) | — | L27 |
velocityActual01 | U32 | Input (slave → master) | 0x2004:0x00 (PDO 0x1a04, SM 3) | — | L28 |
systemTimeL32_01 | U32 | Input (slave → master) | 0x2000:0x00 (PDO 0x1a04, SM 3) | — | L29 |
alarms01 | U16 | Input (slave → master) | 0x6503:0x00 (PDO 0x1a04, SM 3) | — | L30 |
warnings01 | U16 | Input (slave → master) | 0x6505:0x00 (PDO 0x1a04, SM 3) | — | L31 |
temperatureActual01 | S32 | Input (slave → master) | 0x2120:0x00 (PDO 0x1a04, SM 3) | — | L32 |