Beckhoff_7XXX/ELM

Entry declarations below are shown as written, before macro expansion. Conditional entries require the corresponding options. See the reference guide for naming, direction and inclusion rules.

Scripts and snippets

ecmcELM7222-0010.cmd

Source: hardware/Beckhoff_7XXX/ELM/ecmcELM7222-0010.cmd

Documented configuration options:

  • [out] SDO 0x1011:01 –> 1684107116 \b reset
Entry identifierTypeDirectionObject / data sourceCondition prefixSource
driveControl01U16Output (master → slave)0x7010:0x01 (PDO 0x1610, SM 2)—L41
velocitySetpoint01S32Output (master → slave)0x7010:0x06 (PDO 0x1612, SM 2)—L42
positionActual01U32Input (slave → master)0x6000:0x11 (PDO 0x1a00, SM 3)—L44
driveStatus01U16Input (slave → master)0x6010:0x01 (PDO 0x1a10, SM 3)—L45
driveControl02U16Output (master → slave)0x7110:0x01 (PDO 0x1650, SM 2)—L56
velocitySetpoint02S32Output (master → slave)0x7110:0x06 (PDO 0x1652, SM 2)—L57
positionActual02U32Input (slave → master)0x6100:0x11 (PDO 0x1a40, SM 3)—L59
driveStatus02U16Input (slave → master)0x6110:0x01 (PDO 0x1a50, SM 3)—L60

ecmcELM7222-0010_OPT.cmd

Source: hardware/Beckhoff_7XXX/ELM/ecmcELM7222-0010_OPT.cmd

Documented configuration options:

  • MODE CSV (default), CSP, CST or CSTCA; MODE_1/MODE_2 override per channel
  • TP Touch-probe status PDO, default 0; supported: 1
  • INFO2 Default NONE; see hugo/content/manual/knowledgebase/hardware/EX72xx_OPT.md for capabilities
  • DIAG Actual velocity, torque and voltage PDOs, default 0
  • ENC_STAT 0 or 1; default 1

Referenced hardware snippets (may be conditional):

No direct entry declarations; follow the referenced snippets above.

ecmcELM7231-0010.cmd

Source: hardware/Beckhoff_7XXX/ELM/ecmcELM7231-0010.cmd

Documented configuration options:

  • [out] SDO 0x1011:01 –> 1684107116 \b reset
Entry identifierTypeDirectionObject / data sourceCondition prefixSource
driveControl01U16Output (master → slave)0x7010:0x01 (PDO 0x1610, SM 2)—L41
velocitySetpoint01S32Output (master → slave)0x7010:0x06 (PDO 0x1612, SM 2)—L42
positionActual01U32Input (slave → master)0x6000:0x11 (PDO 0x1a00, SM 3)—L44
driveStatus01U16Input (slave → master)0x6010:0x01 (PDO 0x1a10, SM 3)—L45

ecmcELM7231-0010_OPT.cmd

Source: hardware/Beckhoff_7XXX/ELM/ecmcELM7231-0010_OPT.cmd

Documented configuration options:

  • MODE CSV (default), CSP, CST or CSTCA; MODE_1/MODE_2 override per channel
  • TP Touch-probe status PDO, default 0; supported: 1
  • INFO2 Default NONE; see hugo/content/manual/knowledgebase/hardware/EX72xx_OPT.md for capabilities
  • DIAG Actual velocity, torque and voltage PDOs, default 0
  • ENC_STAT 0 or 1; default 1

Referenced hardware snippets (may be conditional):

No direct entry declarations; follow the referenced snippets above.