Festo

Entry declarations below are shown as written, before macro expansion. Conditional entries require the corresponding options. See the reference guide for naming, direction and inclusion rules.

Scripts and snippets

ecmcFesto-CMMT-ST.cmd

Source: hardware/Festo/ecmcFesto-CMMT-ST.cmd

Documented configuration options:

  • [out] SDO 0x1011:01 –> 1684107116 \b reset

Referenced hardware snippets (may be conditional):

No direct entry declarations; follow the referenced snippets above.

ecmcFesto-CMMT-ST_CSP.cmd

Source: hardware/Festo/ecmcFesto-CMMT-ST_CSP.cmd

Documented configuration options:

  • [out] SDO 0x1011:01 –> 1684107116 \b reset

Referenced hardware snippets (may be conditional):

No direct entry declarations; follow the referenced snippets above.

ecmcFesto-CMMT-ST_PDO.cmd

Source: hardware/Festo/ecmcFesto-CMMT-ST_PDO.cmd

Documented configuration options:

  • [out] SDO 0x1011:01 –> 1684107116 \b reset
Entry identifierTypeDirectionObject / data sourceCondition prefixSource
driveControl0116 bits (legacy)Output (master → slave)0x6040:0x00 (PDO 0x1600, SM 2)—L21
modeControl018 bits (legacy)Output (master → slave)0x6060:0x00 (PDO 0x1600, SM 2)—L23
positionSetpoint0132 bits; signed=1Output (master → slave)0x607A:0x00 (PDO 0x1600, SM 2)—L24
profileVelocitySetpoint0132 bits; signed=1Output (master → slave)0x6081:0x00 (PDO 0x1600, SM 2)—L25
velocitySetpoint0132 bits; signed=1Output (master → slave)0x60FF:0x00 (PDO 0x1600, SM 2)—L26
torqueSetpoint0116 bits; signed=1Output (master → slave)0x6071:0x00 (PDO 0x1600, SM 2)—L27
velocityOffset0132 bits; signed=1Output (master → slave)0x60B1:0x00 (PDO 0x1600, SM 2)—L28
torqueOffset0116 bits; signed=1Output (master → slave)0x60B2:0x00 (PDO 0x1600, SM 2)—L29
binaryOutputWd0132 bits; signed=0Output (master → slave)0x60FE:0x1 (PDO 0x1600, SM 2)—L30
driveStatus0116 bits (legacy)Input (slave → master)0x6041:0x0 (PDO 0x1a00, SM 3)—L33
modeStatus018 bits; signed=1Input (slave → master)0x6061:0x0 (PDO 0x1a00, SM 3)—L34
positionActual0132 bits; signed=1Input (slave → master)0x6064:0x0 (PDO 0x1a00, SM 3)—L35
positionActual0232 bits; signed=1Input (slave → master)0x60E4:0x1 (PDO 0x1a00, SM 3)—L36
velocityActual0132 bits; signed=1Input (slave → master)0x606C:0x0 (PDO 0x1a00, SM 3)—L37
velocityActual0232 bits; signed=1Input (slave → master)0x60E5:0x1 (PDO 0x1a00, SM 3)—L38
torqueActual0116 bits; signed=1Input (slave → master)0x6077:0x0 (PDO 0x1a00, SM 3)—L39
binaryInputWd0132 bits; signed=0Input (slave → master)0x60FD:0x0 (PDO 0x1a00, SM 3)—L40

ecmcFesto-CMMT-ST_PV.cmd

Source: hardware/Festo/ecmcFesto-CMMT-ST_PV.cmd

Documented configuration options:

  • [out] SDO 0x1011:01 –> 1684107116 \b reset

Referenced hardware snippets (may be conditional):

No direct entry declarations; follow the referenced snippets above.

ecmcFesto-VAEM-L1-S-16-PT.cmd

Source: hardware/Festo/ecmcFesto-VAEM-L1-S-16-PT.cmd

Entry identifierTypeDirectionObject / data sourceCondition prefixSource
binaryOutputArray0116 bits (legacy)Output (master → slave)0x7000:0x1 (PDO 0x1600, SM 2)—L15
binaryOutputArray0216 bits (legacy)Output (master → slave)0x7000:0x2 (PDO 0x1600, SM 2)—L16