Entry declarations below are shown as written, before macro expansion. Conditional entries require the corresponding options. See the reference guide for naming, direction and inclusion rules.
Source: hardware/Sensors/el6224_outputs/ecmcEL6224-Sensor-chX_output.cmd
| Entry identifier | Type | Direction | Object / data source | Condition prefix | Source |
|---|---|---|---|---|---|
BO_${ECMC_EC_CH_ID_TEXT} | U16 | Input (slave → master) | 0x70${ECMC_EC_CH_ID}0:0x01 (PDO 0x160${ECMC_EC_CH_ID}, SM 2) | — | L14 |