Servotronix

Entry declarations below are shown as written, before macro expansion. Conditional entries require the corresponding options. See the reference guide for naming, direction and inclusion rules.

Scripts and snippets

ecmcCD02.cmd

Source: hardware/Servotronix/ecmcCD02.cmd

Entry identifierTypeDirectionObject / data sourceCondition prefixSource
driveControl01U16Output (master → slave)0x6040:0x0 (PDO 0x1600, SM 2)—L22
modesOp01S8Output (master → slave)0x6060:0x0 (PDO 0x1600, SM 2)—L23
positionSetpoint01S32Output (master → slave)0x607a:0x0 (PDO 0x1600, SM 2)—L24
touchProbeControl01U16Output (master → slave)0x60b8:0x0 (PDO 0x1600, SM 2)—L25
velocitySetpoint01S32Output (master → slave)0x60ff:0x0 (PDO 0x1601, SM 2)—L28
torqueSetpoint01S16Output (master → slave)0x6071:0x0 (PDO 0x1601, SM 2)—L29
driveStatus01U16Input (slave → master)0x6041:0x0 (PDO 0x1a00, SM 3)—L36
modesOpDisplay01S8Input (slave → master)0x6061:0x0 (PDO 0x1a00, SM 3)—L37
positionActual01S32Input (slave → master)0x6064:0x0 (PDO 0x1a00, SM 3)—L38
torqueActual01S16Input (slave → master)0x6077:0x0 (PDO 0x1a00, SM 3)—L39
errorCode01U16Input (slave → master)0x603f:0x0 (PDO 0x1a00, SM 3)—L40
binaryInputArray01U32Input (slave → master)0x60fd:0x0 (PDO 0x1a00, SM 3)—L41
touchProbeStatus01U16Input (slave → master)0x60b9:0x0 (PDO 0x1a01, SM 3)—L44
touchProbePosition01S32Input (slave → master)0x60ba:0x0 (PDO 0x1a01, SM 3)—L45
velocityActual01S32Input (slave → master)0x606c:0x0 (PDO 0x1a01, SM 3)—L46